| dc.contributor.author | Umbría Jiménez, Francisco | |
| dc.contributor.author | Gordillo, Francisco | |
| dc.contributor.author | Gómez-Estern Aguilar, Fabio | |
| dc.contributor.author | Salas, Francisco | |
| dc.contributor.author | Portillo, Ramón C. | |
| dc.contributor.author | Vázquez, Sergio | |
| dc.date.accessioned | 2023-10-30T15:06:02Z | |
| dc.date.available | 2023-10-30T15:06:02Z | |
| dc.date.issued | 2014 | |
| dc.identifier.issn | 1873-6939 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12412/4437 | |
| dc.description.abstract | This paper addresses the problems associated with the dc-link capacitor voltages of the three-level neutral-point-clamped power converter: the imbalance of the capacitor voltages as well as the presence of an ac-voltage low-frequency oscillation in the dc link of the converter. In order to cope with them, a mathematical analysis of the capacitor voltage difference dynamics, based on a direct
average continuous model, is carried out, considering a singular perturbation approach. The analysis leads to a final expression where a sinusoidal disturbance appears explicitly. Consequently, the two problems can be handled together using the ordinary formulation of a problem of regulating the output of a system subject to sinusoidal disturbances, applying classical control theory to
design the controller. In this way, the controller is designed including the disturbance estimate provided by a Luenberger observer to asymptotically cancel the disturbance, while keeping also balanced the capacitor voltages. Experiments for a synchronous three-level neutral-point-clamped converter prototype are carried out to evaluate the performance and usefulness of the converter working as a grid-connected inverter under the proposed control law. | es |
| dc.language.iso | spa | es |
| dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
| dc.title | Voltage balancing in three-level neutral-point-clamped converters via Luenberger observer | es |
| dc.type | article | es |
| dc.identifier.doi | 10.1016/j.conengprac.2013.12.003 | |
| dc.journal.title | Control Engineering Practice | es |
| dc.page.initial | 36 | es |
| dc.page.final | 44 | es |
| dc.relation.projectID | MICINN-FEDER DPI2009-09661 and Junta de Andalucıa P07-TIC-02991 | es |
| dc.rights.accessRights | openAccess | es |
| dc.subject.keyword | Luenberger observer | es |
| dc.subject.keyword | Disturbance rejection | es |
| dc.subject.keyword | Voltage balancing | es |
| dc.subject.keyword | Neutral-point-clamped (NPC) converter | es |
| dc.subject.keyword | Multilevel power converter | es |
| dc.volume.number | 25 | es |